EasyManua.ls Logo

Huawei FusionServer RH2288H V3 - Page 24

Huawei FusionServer RH2288H V3
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Huawei SAP HANA Appliance Single Node Installation
Guide (RH2288H V3+Broadwell+SLES11 SP4 For B1)
3 Configuring RAID Parameters
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
19
Figure 3-12 VD1 Configuration page
Step 8 Configure the VD1 Advanced RAID Parameter Item, and select the "OK" to complete the
configuration, as show in Figure 3-13;
Strip Size=128KB
Read Policy=Normal
Write Policy=Write Back With BBU
Disk cache Policy = unchanged
Initialize=[X]
Figure 3-13 VD1 Advanced Configuration
Step 9 When you complete the all VD1 RAID Configuration Item, select "OK" and complete the
VD1 configure, as show in Figure 3-14