Huawei SAP HANA Appliance Single Node Installation
Guide (RH2288H V3+Broadwell+SLES11 SP4 For B1)
3 Configuring RAID Parameters
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
22
Figure 3-18 Create CacheCade virtual Drive
Step 14 When you select "Create CacheCade virtual Drive "item, enter the RAID configuration
parameters page,this example, there are 4 SSD disks configured as RAID1; "Write Policy
"parameter should be set to "Write Back"; select the 4 disks, select "OK", as show in Figure
3-19;
Figure 3-19 Cachecade Configuration page
Step 15 When you complete the all CacheCade Configuration Item, select "OK" to continuse, as show
in Figure 3-20.