LampSite Solution
Product Description
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Table 2-4 describes the RHUB3908 indicators.
Table 2-4 RHUB3908 indicators
There is power supply, but the RHUB is
faulty.
There is no power supply, or the RHUB is
faulty.
Blinking on for
1s and off for 1s
The RHUB is functioning properly.
Blinking on for
0.125s and off
for 0.125s
The RHUB is loading software,
configuring data, not working, or the
software is in security version.
Alarms have been generated, and the
device must be replaced.
No alarms have been generated.
Blinking on for
1s and off for 1s
At least one alarm has been reported. The
RHUB may have to be replaced.
The RHUB is activated and functioning
normally.
The RHUB is not activated.
Blinking on for
1s and off for 1s
The device is under commissioning.
The CPRI link is functioning properly.
An optical module has failed to transmit or
receive signals because the optical module
is faulty or the optical fiber is broken.
Blinking red on
for 1s and off for
1s (red)
The CPRI link is out of lock possibly
because the dual-mode clock sources are
not synchronous or the data rates over
CPRI ports do not match.
The optical module is not detected or is
powered off.
GE0/1
This indicator
is on
only when the
PHS feature
is enabled.
The connection is set up.
No connection is detected.
Data has been transmitted or received.
No data has been transmitted or received.
The RHUB is supplying power to the
pRRU properly.