EasyManua.ls Logo

Huawei ME909 Series - Power Supply Features

Huawei ME909 Series
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUAWEI ME909 Series LTE LGA Module
Hardware Guide
Electrical and Reliability Features
Issue V0.3 (2013-05-21)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
52
5.5 Electrical Features of Application Interfaces
Table 5-4 lists electrical features (typical values).
Table 5-4 Electrical features of application interfaces
Parameter
Description
Minimum Value
Maximum Value
Unit
V
IH
Logic high-level
input voltage
0.65 x V
DD_PX
V
DD_PX
+ 0.3
V
V
IL
Logic low-level
input voltage
0.3
0.35 x V
DD_PX
V
V
OH
Logic high-level
output voltage
V
DD_PX
0.45
V
DD_PX
V
V
OL
Logic low-level
output voltage
0
0.45
V
5.6 Power Supply Features
5.6.1 Input Power Supply
Table 5-5 lists the requirements for input power of the ME909 module.
Table 5-5 Requirements for input power for the ME909 module
Parameter
Min.
Typ.
Max.
Ripple
Unit
VBAT
3.3
3.8
4.2
0.05
V
Figure 5-1 Power Supply During Burst Emission
The VBAT Minimum value must be guaranteed during the burst (with 2.5 A Peak in GSM, GPRS
or EGPRS mode).

Table of Contents