HUAWEI MU609 HSPA LGA Module
Application Guide
FOTA Application Scenarios
Issue 02 (2013-09-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
119
16.2 Setting FOTA Mode
16.2.1 Reference Process
Command
Description
AT^FOTAMODE=?
Check the parameter range supported by
the command.
^FOTAMODE: (0-1),(0-1),(0-1),(0-
1),(1-65535)
OK
AT^FOTAMODE?
Query the current settings.
^FOTAMODE: 0,0,0,1,7
OK
Return the current FOTA mode: manual
query, manual download, manual upgrade,
and resumable data transfer enabled
The value 7 indicates that the query cycle is
seven days, which is meaningless when
manual query is used.
AT^FOTAMODE=1,1,1,1,15
Configure FOTA mode as auto query, auto
download, auto upgrade, and resumable
data transfer enabled. And the auto query
cycle is set to 15 days.
OK
Notes:
Parameter settings are all saved upon power-off.
All parameters will be restored to their default values after the upgrade.
16.2.2 Troubleshooting
Scenario
Possible Error
Information
Solution
An error message is
returned.
+CME ERROR: Error
command parameters
The parameter is incorrectly
set. For details, see the latest
version of MU609 V100R002
in HUAWEI MU609 HSPA
LGA Module AT Command
Interface Specification.