HUAWEI MU609 HSPA LGA Module 
Hardware Guide   
Description of the Application Interfaces 
 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
 
Figure 3-2  Recommended power circuit of MU609 module 
 
 
When the system power restarts, a discharge circuit is recommended to make sure 
the power voltage drops below 1.9 V for 1s at least.   
3.3.3 Output Power Supply Interface 
Output power supply interface is VCC_EXT1.   
Through the output power supply interface, the MU609 module can supply 1.8 V 
power externally with an output current of 10 mA (typical value) for external level 
conversion or other applications. 
If the MU609 module is in sleep mode, the output power supply interface is in the low 
power consumption state (< 500 μA). If the MU609 module is in power down mode, 
the output power supply is in the disabled state. 
3.4 Signal Control Interface 
3.4.1 Overview 
The signal control part of the interface in the MU609 module consists of the following: 
 
Power-on/off (POWER_ON_OFF) pin 
 
System reset (RESIN_N) pin 
 
WAKEUP_IN Signal (WAKEUP_IN) pin 
 
WAKEUP_OUT Signal (WAKEUP_OUT) pin 
 
SLEEP_STATUS Signal (SLEEP_STATUS) pin 
 
LED signal (LED_MODE) pin 
Table 3-3 lists the pins on the signal control interface. 
Table 3-3  Definitions of the pins on the signal control interface 
Pin for controlling power-on and