EasyManua.ls Logo

Huawei MU609 - Operating and Storage Temperatures and Humidity; Power Supply Features; Input Power Supply

Huawei MU609
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUAWEI MU609 HSPA LGA Module
Hardware Guide
Electrical and Reliability Features
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
52
5.3 Operating and Storage Temperatures and Humidity
Table 5-2 lists the operating and storage temperatures and humidity for the MU609
module.
Table 5-2 operating and storage temperatures and humidity for the MU609 module
Specification
Min.
Max.
Unit
Normal working temperatures
20
+70
°C
Extended temperatures
[1]
40
+85
°C
Ambient temperature for storage
40
+85
°C
[1]: When the MU609 module works in the range of 40°C to 20°C or +70°C to +85°C , NOT all
its RF performances comply with 3GPP specifications.
5.4 Power Supply Features
5.4.1 Input Power Supply
Table 5-3 lists the requirements for input power of the MU609 module.
Table 5-3 Requirements for input power for the MU609 module
Parameter
Min.
Typ.
Max.
Ripple
Unit
VBAT
3.3
3.8
4.2
0.1
V
Figure 5-1 Power Supply During Burst Emission
The VBAT minimum value must be guaranteed during the burst (with 2. 5 A Peak in GPRS or
GSM mode).