HUAWEI MU609 HSPA LGA Module
Hardware Guide
Electrical and Reliability Features
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
54
Description
Bands
Test Value (mA)
Notes/Configuration
Typical
Idle
HSPA+/WCDMA
UMTS bands
20
Module is powered up.
DRX cycle=8 (2.56s)
Module is registered on the
network, no data is transmitted.
USB is in active.
GPRS/EDGE
GSM bands
20
Module is powered up.
MFRMS=5 (1.175s)
Module is registered on the
network, no data is transmitted.
USB is in active
Radio Off
All bands
17
Module is powered up.
RF is disabled.
USB is in active.
Table 5-7 Averaged Data Transmission DC power consumption of MU609
(HSPA/WCDMA)
Description
Band
Test Value (mA)
Power (dBm)
Typical
WCDMA
Band 1
(IMT2100)
290
1 dBm Tx Power
350
10 dBm Tx Power
680
23.5 dBm Tx Power
Band 2
(PCS 1900)
300
1 dBm Tx Power
360
10 dBm Tx Power
705
23.5 dBm Tx Power
Band 5
(850 MHz)
260
1 dBm Tx Power
300
10 dBm Tx Power
600
23.5 dBm Tx Power
Band 8
(900 MHz)
300
1 dBm Tx Power
320
10 dBm Tx Power
640
23.5 dBm Tx Power
HSDPA
Band 1
(IMT2100)
380
1 dBm Tx Power
430
10 dBm Tx Power