5 Health indicator 6 Network port Link indicator
7 NMI button 8 Power button/indicator
9 UID button/indicator 10 USB 2.0 port
11 USB 2.0 port 12 VGA port
13 Label (including ESN label) - -
Table 4-33 describes the indicators and buttons on the quorum server front panel.
Table 4-33 Indicators and buttons on the front panel
Number
Meaning Color State Description
4 Fault diagnosis
LED
None
l ---: The quorum server is
operating properly.
l Error Code: A fault occurs in
quorum server hardware.
8 Power button/
indicator
Yellow and
green
l Off: The quorum server is not
powered on.
l Blinking yellow: The system is
being started.
l Steady yellow: The system is
in the standby state.
l Steady green: The system is
properly powered on.
NOTE
You can hold down the power button
for 6 seconds to power off the quorum
server.
9 UID button/
indicator
Blue The UID button/indicator helps
identify and locate a quorum
server in a rack. You can turn on
or off the UID indicator by
manually pressing the UID button
or remotely running a command
on the iBMC CLI.
l Steady on: The quorum server
is located.
l Off: The quorum server is not
located.
l You can hold down the UID
button for 4 to 6 seconds to
reset the system.
OceanStor 2600 V3
Product Description
4 Hardware Architecture
Issue 09 (2019-05-15) Copyright © Huawei Technologies Co., Ltd. 94

Table of Contents

Other manuals for Huawei OceanStor 2600 V3