Module No. Indicator Status and Description
7 Power
indicator of
the controller
l Steady green: The controller is powered on.
l Blinking green (0.5 Hz): The controller
enclosure is powered on and in the BIOS boot
process.
l Blinking green (2 Hz): The controller is in the
operating system boot process, or the controller
is in the power-off process.
l Off: The controller is absent or powered off.
8 Alarm
indicator of
the controller
l Steady red: An alarm is generated on the
controller.
l The Alarm indicator blinking red and the Power
indicator blinking green: The controller is being
located.
l Off: The controller is working correctly.
9 Indicator of
the mini SAS
HD
expansion
port
l Steady blue: Data is transferred to the
downstream disk enclosure at the rate of 4 x 12
Gbit/s.
l Steady green: Data is transferred to the
downstream disk enclosure at the rate of 4 x 3
Gbit/s or 4 x 6 Gbit/s.
l Steady red: The port is faulty.
l Off: The link to the port is down.
10 Link/Active
indicator of
the GE
electrical
port
l Steady green: The link to the application server
is normal.
l Blinking green: Data is being transferred.
l Off: The link to the application server is down
or no link exists.
11 Speed
indicator of
the GE
electrical
port
l Steady orange: The data transfer rate between
the storage system and the application server is
1 Gbit/s.
l Off: The data transfer rate between the storage
system and the application server is less than 1
Gbit/s.
4.3 2 U Disk Enclosure (2.5-Inch Disks)
This section describes a disk enclosure in terms of its hardware structure, component
functions, front and rear views, and indicators.
OceanStor 2600 V3
Product Description
4 Hardware Architecture
Issue 09 (2019-05-15) Copyright © Huawei Technologies Co., Ltd. 49