Table 7-8 Heat dissipation parameters of a storage system
Device Maximum Heat Dissipation
Controller enclosure
12 disk slots: 1628 BTU
a
/h
25 disk slots: 1773 BTU/h
2 U disk enclosure 914 BTU/h
4 U disk enclosure 1610 BTU/h
4 U high-density disk enclosure 4265.00 BTU/h
a: BTU, British Thermal Unit.
Noise
The disks and fans make noise when in operation, with fans being the major noise source. The
intensity of fan rotation is associated with the temperature. A higher temperature leads to
greater rotational speed by the fans, which in return creates greater noise. Therefore, there is a
direct correlation between the noise made by a storage system and the ambient temperature in
the equipment room.
When the temperature is 25°C, the parameters of the noise generated by the storage system
are listed in Table 7-9.
Table 7-9 Noise parameters of a storage system
Device
Noise Power
800 W power configured 61.3 dB (25°C)
600 W power configured 65.7 dB (25°C)
OceanStor 2600 V3