Module Indicator Color Status Description
Link indicator of
the mini SAS
expander port
Green On The disk channel is normal.
- Off The disk channel is abnormal.
Link indicator of
the FC host port
Green On The link to the ASs is normal.
- Off The link to the ASs is abnormal.
Rate indicator of
the FC host port
Green On The data transmission rate between
the storage system and the ASs is 4
Gbit/s.
- Off The data transmission rate between
the storage system and the ASs is 2
Gbit/s or 1 Gbit/s.
Active indicator
of the mini SAS
host port
Orange Blinking Data is being transmitted.
- Off No data is being transmitted.
Link indicator of
the mini SAS
host port
Green On The link to the ASs is normal.
- Off The link to the ASs is abnormal.
Active indicator
of the iSCSI host
port
Orange Blinking Data is being transmitted.
- Off No data is being transmitted.
Link indicator of
the iSCSI host
port
Green On The link to the ASs is normal.
- Off The link to the ASs is abnormal.
Procedure
l Observe the status of the relevant indicators on the S2600 controller enclosure.
----End
Exception Handling
l If the startup/alarm indicator of the controller enclosure is red, power on the controller
enclosure again.
If the fault still exists, contact the technical support engineers.
l If the power indicator of the controller enclosure is off, power on the controller enclosure.
If the fault still exists, contact the technical support engineers.
l If the disk running indicator is off, reinsert the disk. If the running indicator is still off,
change the disk.
If the fault still exists, contact the technical support engineers.
l If the disk alarm/location indicator is red, see the
OceanStor S2600 Storage System
Routine Maintenance 3 On-Site Routine Maintenance Guide