l If the disk alarm/location indicator is red, see the
“Turning On of the Disk Alarm/Location Indicator” in the OceanStor S2600 Storage
System Troubleshooting.
l If the fan running/alarm indicator is red, see the
“Turning On of the Fan Running/Alarm Indicator” in the OceanStor S2600 Storage
System Troubleshooting.
l If the power running/alarm indicator is red, power on the PEM again. If the power running/
alarm indicator is still red, change the PEM.
If the fault still exists, contact the technical support engineers.
l If the power indicator of the expander module is off, power on the expander module again.
If the power indicator is still off, change the expander module.
If the fault still exists, contact the technical support engineers.
l If the alarm indicator of the expander module is red, contact the technical support engineers.
l If the link indicator of the mini SAS expander port is off, see the
“0x20030178F Expander port link down” in the OceanStor S2600 Storage System Event
Reference.
----End