Pin Assignment
Table 3-9, Table 3-10, and Table 3-11 describe the labels and recommended connections for
the branch cables of the CRPI optical cable.
Table 3-9 Labels and recommended connections for the branch cables of the multi-mode optical
cable between the BBU and RRU
Label Color Installation Position
1A Orange CPRI RX port on the RRU
1B Gray CPRI TX port on the RRU
2A Orange TX port on the BBU
2B Gray RX port on the BBU
 
Table 3-10 Labels and recommended connections for the branch cables of the multi-mode
optical cable between RRUs
Label Color Installation Position
1A Orange CPRI RX port on the RRU 1
1B Gray CPRI TX port on the RRU 1
2A Orange CPRI TX port on the RRU 0
2B Gray CPRI RX port on the RRU 0
 
Table 3-11 Labels and recommended connections for the branch cables of the single-mode
optical cable and recommended connections
Label
Color Installation Position
1A Yellow RX port on the BBU or CPRI RX port
on the RRU
1B Blue TX port on the BBU or CPRI TX port on
the RRU
2A Yellow ODF
2B Blue ODF
 
3.7 Alarm Cable for the DC RRU
The alarm cable for the RRU is a shielded straight-through cable. The cable transmits alarm
signals from the external equipment to the DC RRU and monitors the external equipment.