If a single ladder is used, ensure that the wider end of the ladder is at the
bottom, and take protective measures to prevent the ladder from sliding.
If a single ladder is used, do not climb higher than the fourth rung of the
ladder from the top.
If you use a single ladder to climb up to a platform, ensure that the ladder is
at least 1 m higher than the platform.
Hoisting
Only trained and qualied personnel are allowed to perform hoisting
operations.
Install temporary warning signs or fences to isolate the hoisting area.
Ensure that the foundation where hoisting is performed on meets the load-
bearing requirements.
Before hoisting objects, ensure that hoisting tools are rmly secured onto a
xed object or wall that meets the load-bearing requirements.
During hoisting, do not stand or walk under the crane or the hoisted objects.
Do not drag steel ropes and hoisting tools or bump the hoisted objects
against hard objects during hoisting.
Ensure that the angle between two hoisting ropes is no more than 90
degrees, as shown in the following gure.
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual 1 Safety Information
Issue 18 (2024-03-10) Copyright © Huawei Technologies Co., Ltd. 11

Table of Contents

Other manuals for Huawei SUN2000-40KTL-M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-40KTL-M3 and is the answer not in the manual?

Huawei SUN2000-40KTL-M3 Specifications

General IconGeneral
Max. Efficiency98.7%
European Efficiency98.4%
Max. Input Voltage1100 V
MPPT Operating Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated Output Power40000 W
Rated AC Voltage400 V
Rated AC Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)<3%
DC Reverse-Polarity ProtectionYes
AC Overcurrent ProtectionYes
DC Surge ProtectionType II
AC Surge ProtectionType II
Insulation MonitoringYes
Residual Current MonitoringYes
DC SwitchYes
Protection ClassIP66
Operating Temperature Range-25°C to +60°C
Relative Humidity (Operating)0% - 100%
CoolingNatural Convection
Max. Apparent AC Power44000 VA
AC Voltage Range320 V - 480 V
Operating Altitude4000 m
DisplayLED Indicators
CommunicationRS485, WLAN
Weight43 kg
Max. DC Power60000 W