EasyManuals Logo

Huawei SUN2000-40KTL-M3 User Manual

Huawei SUN2000-40KTL-M3
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Symbol Description
Indicates a potentially hazardous situation which,
if not avoided, could result in equipment damage,
data loss, performance deterioration, or
unanticipated results.
NOTICE is used to address practices not related to
personal injury.
Supplements the important information in the
main text.
NOTE is used to address information not related
to personal injury, equipment damage, and
environment deterioration.
Change History
Changes between document issues are cumulative. The latest document issue
contains all the changes made in earlier issues.
Issue 18 (2024-03-10)
Added 7.3.2 Setting Feed-in at Limited Current.
Updated A Grid Codes.
Issue 17 (2024-02-02)
Updated 10 Technical Specications.
Issue 16 (2024-01-12)
Updated 2.2 Appearance.
Updated 3 Inverter Storage.
Updated 4.4 Moving the Inverter.
Updated 5.1 Precautions.
Updated 5.2 Preparing Cables.
Updated 5.4 Connecting an AC Output Power Cable.
Updated 5.5.1 Cable Connection Description.
Updated 8.3 Alarm Reference.
Updated 10 Technical Specications.
Updated A Grid Codes.
Updated L Contact Information.
SUN2000-(20KTL, 29.9KTL, 30KTL, 36KTL, 40KTL)-
M3
User Manual About This Document
Issue 18 (2024-03-10) Copyright © Huawei Technologies Co., Ltd. iii

Table of Contents

Other manuals for Huawei SUN2000-40KTL-M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-40KTL-M3 and is the answer not in the manual?

Huawei SUN2000-40KTL-M3 Specifications

General IconGeneral
Max. Efficiency98.7%
European Efficiency98.4%
Max. Input Voltage1100 V
MPPT Operating Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated Output Power40000 W
Rated AC Voltage400 V
Rated AC Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading - 0.8 lagging
Total Harmonic Distortion (THD)<3%
DC Reverse-Polarity ProtectionYes
AC Overcurrent ProtectionYes
DC Surge ProtectionType II
AC Surge ProtectionType II
Insulation MonitoringYes
Residual Current MonitoringYes
DC SwitchYes
Protection ClassIP66
Operating Temperature Range-25°C to +60°C
Relative Humidity (Operating)0% - 100%
CoolingNatural Convection
Max. Apparent AC Power44000 VA
AC Voltage Range320 V - 480 V
Operating Altitude4000 m
DisplayLED Indicators
CommunicationRS485, WLAN
Weight43 kg
Max. DC Power60000 W

Related product manuals