Always check the simplest possible cause of a malfunction first. For example, a loose or disconnected trigger
line. Then proceed logically, eliminating each possible cause until the defective part is located. Where possible,
substitute known good parts for suspected defective parts. Use Trouble Shooting Chart as an aid for locating
and correcting trouble.
1. Tool fails to operate when trigger is depressed.
a. Inoperative POWERIG® Hydraulic Unit. Check
power source and/or see applicable Powerig
instruction manual.
b. Loose or disconnected control cord.
c. Damaged trigger assembly.
d. Loose or faulty hydraulic hose couplings.
2. Tool leaks hydraulic fluid.
a. Defective Tool O-rings or loose hose connections
at Tool.
3. Hydraulic couplers leak fluid.
a. Damaged or worn O-rings in coupler body.
4. Hydraulic fluid overheats.
a. Powerig not operating properIy.
b. Hydraulic couplers not completely tightened.
d. Restriction in hydraulic line.
5. Tool operates erratically and fails to install fastener
properly.
a. Low or erratic hydraulic pressure; air in system
b. Damaged or worn piston/anvil O-ring in Tool.
c. Excessive wear on sliding surfaces of Tool parts.
d. Relief Valve too short, worn, or peened over.
6. Collar of HUCKBOLT® fastener not completely
swaged.
a. Improper Tool operation. See Trouble 5.
b. Scored anvil.
7. Tool “hangs-up on swaged collar of HUCKBOLT
Fastener.
a. Improper Tool operation. See Trouble 5.
b. RETURN pressure too low.
8. Pintail of fastener fails to break.
a. Improper Tool operation. See Trouble 5.
b. Pull grooves on fastener stripped. See Trouble 10.
c. PULL pressure too low.
9. Jaw segments do not maintain proper position in
piston.
a. Incorrect amount of follower O-rings. Clean before
reassembling.
10. Pull grooves on fastener pintail stripped during
PULL stroke.
a. Broken pintail not removed from tool.
b. Anvil was not slid completely onto fastener pintail.
c. Incorrect fastener length.
d. Worn or damaged jaw segments.
e. Metal particles accumulated in pull grooves of
jaw segments.
f. Excessive sheet gap.
11. Tool operates in reverse.
a. Reversed hydraulic hose connections between
POWERIG and tool.
12. Anvil will not slide completely over fastener pintail.
a. Broken pintail not removed from tool.
b. Incorrect fastener length.