HIDDEN AND ADVANCED FEATURES
Feature Where Found Description
PROGRAMMABLE SENSOR OVERRIDE
Hold – and turn to Start Times
Sets individual stations to ignore sensor shutdowns. Select stations with ◄ or ►, (use +/
–
) to change
to OFF to ignore sensor.
CYCLE AND SOAK
Hold + and turn to Run Times. Enter Cycle, press PRG to set Soak
Sets max time a station can run at once, and minimum time it must wait before another cycle.
Divides run time into segments to prevent runo.
DELAY BETWEEN STATIONS
Hold – and turn to Run Times
Inserts a delay (seconds or minutes) between stations in a run time, for slow valves or recharging tanks.
HIDE PROGRAMS
Hold – and turn to Water Days
Use +/
–
to change from 4 to 1 to hide extra programs. 1 will show only program A,
start time 1. 4 will show all programs and start times.
SOLAR SYNC DELAY
Hold + and turn to Solar Sync
Set number of days before Solar Sync begins adjusting run times. Allows landscape establishment for a
set period of days, before Solar Sync begins adjusting automatically.
CLIK DELAY
Hold + and turn to O
Set number of days for watering to remain o, aer sensor has been activated and restored.
TOTAL RUN TIME
Turn to Run Times.
Press ◄ when station 1 is shown,
PRG to select other programs.
Calculates and displays total of all run times in a program start time.
TEST PROGRAM
Hold PRG 3 secs.
Runs all stations in controller for the time entered for test or diagnostic purposes.
EASY RETRIEVE
TM
Hold + and PRG to Save
Hold – and PRG to Restore
Saves all program information to restore at a later time.
TOTAL RESET
PRG and RESET button
Erases all watering information.
QUICK CHECK
TM
+, –, ◄, ► together, then +
Checks all stations for wiring problems.
RUN PROGRAM
Hold ►, PRG to select
Runs all stations in selected program; use ► to advance to next station manually.
TROUBLESHOOTING GUIDE
Display Possible Cause Solutions
DISPLAY SHOWS "ERR" WITH NUMBER
Short in eld wiring, or bad solenoid.
Check eld wiring and valve solenoid. Press any button to clear ERR message.
DISPLAY SHOWS P "ERR"
Short in Pump/Master Valve wiring or solenoid.
Check wiring and solenoid at PMV. Check specications for Pump Start Relay.
DISPLAY SHOWS SP "ERR"
SmartPort error. Electrical noise is present near connection to remote or other SmartPort device.
Move connections away from sources of electrical noise.
DISPLAY SHOWS “NO AC”
There is no AC power to the controller.
Check fuse/breaker and incoming power supply to controller.
DISPLAY SHOWS WATERING BUT NO
WATER IS OCCURRING
Problem in eld wiring.Problem with solenoids. No water pressure to system.
Check eld wiring (voltmeter). Check valve solenoid(s). Verify water source is open.
FROZEN OR GARBLED DISPLAY
Power surge
Reset controller.
RAIN SENSOR DOES NOT STOP
IRRIGATION
Jumper wire is not removed. Sensor switch in
BYPASS position.
Remove jumper wire on SEN terminals. Set sensor switch to Active position.
CONTROLLER SEEMS TO WATER
CONTINUOUSLY
Too many start times.
One Start Time operates all stations in a program. Remove unnecessary start times.