What to do if my Hunter X-CORE XC-2 Controller display shows “ERR” with number ERR message?
J
Jessica MillerAug 1, 2025
If the display on your Hunter Controller shows “ERR” followed by a number, it typically indicates a short in the field wiring or a faulty solenoid. You should check the field wiring and valve solenoid to identify and fix the problem.
P
Pam WrightAug 5, 2025
What to do if my Hunter X-CORE XC-2 Controller display shows P “ERR”?
S
Stacie RogersAug 6, 2025
If the display on your Hunter Controller shows P “ERR”, this indicates a short in the P/MV wiring or solenoid. Check the wiring and solenoid at the P/MV, and refer to the specifications for the Pump Start Relay.
J
Justin ThompsonAug 10, 2025
How to fix a frozen or garbled display on my Hunter Controller?
C
Cameron McclainAug 10, 2025
If your Hunter Controller's display is frozen or garbled, it is likely due to a power surge. Try resetting the controller to resolve the issue.
A
Alexander DelacruzAug 14, 2025
What does it mean if my Hunter Controller display shows SP “ERR”?
B
Bruce MartinezAug 15, 2025
If the display on your Hunter Controller shows SP “ERR”, it means that electrical noise is present near the connection to the remote or another SmartPort device. Move the connections away from sources of electrical noise, and verify that the controller has been wired correctly.
N
Nicole AlexanderAug 18, 2025
What to do if my Hunter X-CORE XC-2 seems to water continuously?
M
Michael WilliamsAug 18, 2025
If your Hunter Controller is constantly watering, the issue might be due to having too many START TIMES programmed. Try removing any unnecessary Start Times to resolve this.
M
Mitchell RodriguezAug 23, 2025
What to do if my Hunter X-CORE XC-2 Controller display shows WATERING BUT NO WATERING IS OCCURRING?
J
Jack MillerAug 23, 2025
If your Hunter Controller display indicates watering but no actual watering is happening, there may be a problem in the field wiring. Inspect the field wiring using a voltmeter, check the valve solenoid(s), and ensure that the water source is open.
A
Ashley BensonAug 27, 2025
Why is my Hunter X-CORE XC-2 Controller rain sensor not stopping irrigation?
T
Tricia McdonaldAug 27, 2025
If the rain sensor on your Hunter Controller isn't stopping irrigation, make sure that the jumper wire on the SEN terminals is removed and that the sensor switch is set to the Active position.