22 - English
Safety equipment
NOTE!
After repairing, the chain brake must be in-
spected in line with the instructions below.
Functional inspection:
Do not turn on the engine when carrying out this
inspection.
Hold the chain saw over a stable surface. The
distance between the guide bar and the sur-
face is shown in the table above.
Let go of the front handle and let the chain saw
drop toward the surface underneath.
When the guide bar hits the surface the chain
brake must trigger.
Guide bar length Height
12”-18” 45 cm/18"
WARNING!
Do not touch the muffler until it
has cooled. Risk of burns.
6.3 Dismantling the muffler
1
Use a heat gun to loosen the thread lock on the
screws before you unscrew the two screws for the
spike (A). Remove the spike. See figure 12.
2
Release the two nuts (B) and remove the heat
deflector.
3
Remove the spark arrestor mesh (C).
4
Remove the muffler (D),the gasket (E) and the two
screws (F).
Cleaning and inspection
Clean and check all components carefully. Parts
must be replaced if cracked or show signs of
other defects. Always use original spare parts.
The spark arrestor mesh is best cleaned with a
wire brush.
The mesh must be replaced, if damaged. The
chain saw will overheat if the mesh is clogged
resulting in damage to the cylinder and piston.
Never use a chain saw with a clogged or defec-
tive muffler.
Fig 12
A
B
C
D
E
F
Fig 11