Message Cause Action
Connection set-
tings restored
Settings for wireless connectivity have
been restored due to an error.
Check and revise settings if necessary.
SIM card requires
PIN
The SIM card must be unlocked. Make sure the correct SIM PIN has
been entered into the mower's menu
(Network > SIM card). Contact your lo-
cal Husqvarna representative if this
message appears often.
SIM card locked
The SIM card must be replaced. Contact your local Husqvarna repre-
sentative.
SIM card not found
Automower
®
Connect requires a SIM
card to be inserted in the mower.
Contact your local Husqvarna repre-
sentative.
GeoFence prob-
lem
The GeoFence is not work due to poor
(or no) communication with the system.
Contact your local Husqvarna repre-
sentative.
6.4 Indicator lamp in the charging
station
The indicator lamp in the charging station must show a solid or flashing green light for a correct
installation. If not, follow the instructions in the troubleshooting guide below.
You can also find information on www.husqvarna.com. Speak to your Husqvarna customer service for
more information.
Light Cause Action
Green solid light
Good signals No action required
Green flashing
light
The signals are good and
ECO mode
is
activated.
No action required. For more informa-
tion on
ECO mode
. Refer to
ECO mode
on page 34
.
Blue flashing light
The boundary loop is not connected to
the charging station.
Check that the boundary wire connec-
tors are fitted properly to the charging
station. Refer to
To install the boundary
wire on page 22
.
Break in the boundary loop. Find out where the break is. Replace
the damaged section of the loop with a
new loop wire and splice using an origi-
nal coupler.
Red flashing light
Interruption in the charging station’s an-
tenna.
Contact Husqvarna customer service.
Red solid light
Fault in the circuit board or incorrect
power supply in the charging station.
The fault should be rectified by an au-
thorized service technician.
Contact Husqvarna customer service.
52 - Troubleshooting 1230 - 002 - 30.03.2020