Switching unit on/off
Switch the unit on or off at the main switch (7000). The integrated motor
protection switch protects the electric motor against damage caused by
overloading.
Observe the optical clogging indicator
The unit features two visual clogging indicators with displays of when the
filter element in the filter housing and the coalescing elements are exhausted.
The visual clogging indicator display then switches from green to red.
Item Designation Remedy for red display
100 Clogging indicator, visual, for Replace the filter element in the