Technical data
LVU-CD-40
en(us)
Page 60 / 68
BeWa LVU-CD-40 4035823a en-us 2016-01-08.doc 2016-01-08
Technical data
Dewatering performance
Water separation efficiency > 95% acc. to ISO CD 16332
Achievable water content <200 ppm
Dewatering rate 50 l/h at 5% water in the diesel
Hydraulic data
Operating limit Maximum 10% free water
Maximum flow rate 40 l/min
Pump type Gear pump
Operating pressure Maximum 3 bar
Permissible suction pressure at
suction port.
- 0.9 … 0.2bar
Permissible pressure at pressure
port connection
3 bar
Permissible pressure at the water
drain
0 bar
Connection (suction and pressure
side)
G1“
Water drain G1/2“
Permitted fluid temperature range < 50°C and at least 10°C below the
flash point of the fluid used.
Electrical data
Power supply See motor type plate
Power consumption 750 W
Protection class IP 55
Connector cable, length
- Control type eco 10 m with safety plug
- with control type: Standard or
Premium
0.5 m with safety plug

Table of Contents