This product must be grounded. If it should
malfunction, grounding provides a path of least
resistance for electric current to reduce the risk of
electric shock. The product is equipped with a cord
having an equipment-grounding conductor. The plug
must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all
local codes and ordinances.
DANGER – Improper connection of the equipment-
grounding conductor can result in electrocution. Check
with a qualified electrician or service personnel if you
are in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided with the
product, do not cut off the ground pin – if it will not fit the
outlet, have a proper outlet installed by a qualified
electrician. Do not use any type of adaptor with this
product.
4. To comply with the national electric code, this
pressure washer should only be connected to a
receptacle that is protected by a ground fault circuit
interrupter (GFCI).
5. EXTENSION CORDS: Use of extension cords is
not recommended.
6. NEVER operate an electrically powered washer
after it has tripped a breaker or a ground fault device
without having the reason for the trip determined by an
authorized service engineer or competent electrician.
7. Use only in a dry area. Do not handle electrical
cords and plugs when they are wet, when your hands
are wet, or when standing in water. Do not spray high-
pressure water on to the machine.
8. Disconnect power supply before making any repairs
or adjustments.
9. Transformer on burner is 20,000 volts. Disconnect
battery cable before servicing burner or engine on 12-
volt systems.
FIRE PRECAUTIONS:
1. DO NOT use improper fuels or solvents in this
equipment, and only fill with the correct fluids when the
unit is in an OFF condition, main power is disconnected,
and engine and burner are cool.
NE PAS UTILISER D’ESSENCE, DE PRODUITS DE
VIDANGE NI D’HUILE CONTENANT DE L’ESSENCE OU
DES SOLVANTS
.
2. If equipped with a diesel heated burner system, fill
the diesel burner fuel tank with #2 diesel fuel, kerosene,
or approved alternate fuel. NEVER use gasoline. Do
not confuse gasoline and diesel fuel tanks.
3. NEVER operate this equipment in the presence of
flammable vapors, dust, gases, or other potentially
combustible materials.
4. AVOID contact with the exterior of the coil/heat
exchanger assembly, mufflers, and exhaust port or
stack to prevent burns.
5. DO NOT store fuel or other flammable materials
near the burner or any other open flame.
6. Diesel fired or gasoline power units are designed for
outdoor use and installation only.
7. HE Series (all electric) is designed for indoor use.
8. Natural Gas/propane heated units are for indoor
use only. Venting is required. Outdoor use must be
protected from wind intrusion.
9. Burner on/off switch must be placed in the OFF
position when the pressure washer is not being used.
Do not depend on engine run switch to turn the burner
off – this may cause a safety hazard.
10. Warning: Burner (water heater) should start only
when water is sprayed. Stop the system/engine
immediately if burner continues to fire when trigger gun
is off.
VENTILATION PRECAUTIONS:
1. The HE Series (all electric) functions without the
use of fuel and combustible materials utilizing electricity
for heat generation. Ventilation is only needed for
keeping the eliminating heating build around the
machine
2. Use diesel heated and/or engine powered products
only in well ventilated areas. Exhaust gases contain
carbon monoxide, an odorless, deadly poison.
3. Observe all State, Local, and National codes
providing for indoor use or installation of this unit.
4. Provide adequate ventilation to prevent excess
carbon monoxide levels, engine overheating and
inefficient burner combustion (min. 2’ air space). Do not
restrict normal engine airflow.
5.
THIS MACHINE IS NOT TO BE CONNECTED TO A
TYPE B GAS VENT. NE PAS RACCORDER CET
APPAREIL A UN TUYAU D’EVACUATION DE GAZ DU
TYPE B;
6. For engine driven units mounted in a van or box
truck type vehicles, provide an external engine exhaust
line that is larger in diameter than the factory exhaust
pipe and vent the exhaust to the outside of the vehicle,
but not below the vehicle’s interior floor height. Also,
insure adequate fresh air circulation within the van for
engine cooling purposes to prevent heat build-up and
for engine fresh air intake. Clearance of at least 12” is
recommended on all sides of the unit. Provide a burner
exhaust vent, at least 8” diameter, to the outside
through the van roof, or though the side panel that is at
least 10” in diameter, and position this vent to avoid
water, dirt and debris collection. No flammable liquids,
THIS EQUIPMENT CAN BE HAZARDOUS TO THE OPERATORS
SAFETY AND ONLY AUTHORIZED PERSONNEL WHO HAVE
READ AND UNDERSTOOD THE OPERATION MANUAL SHOULD
BE PERMITTED TO OPERATE THIS UNIT. NEVER ALLOW
CHILDREN TO PLAY ON OR AROUND THIS EQUIPMENT.
Warning: FIRE OR EXPLOSION HAZARD CAN CAUSE
PROPERTY DAMAGE, SEVERE INJURY OR DEATH.