17
RELEASING AIR TRAPPED IN FILTER...
When the pump starts circulang, it will be necessary to release trapped air in the filter.
Carefully loosen the air vent valve counter-clockwise unl there is the hissing sound of air
escaping. Once there is a steady stream of water, close the vent valve, ensuring that the
o-ring does not become pinched.
Turn the Hydrotherapy pump(s) on and re-check for leaks. The control system will
automacally return the pump(s) off aer 15 minutes.
Adjust the hot tub heat control at the topside panel to the desired water temperature.
Adjust water balance (pH, TA, calcium hardness) to recommended levels and add sanizer
once the water temperature reaches 20
o
C (68
o
F).
See secon HOT TUB WATER BALANCE
Keep insulated safety hard cover on the hot tub, and the air controls closed during the enre
heat up process.
NOTE:
In order to prevent damage to your pillows caused by the gassing effect of the chemicals, we
do recommend to remove them when the spa is not in use. By removing them you will
extend considerably the life length of your pillows. We do design ours pillows to be removed
easily in order to make sure they will not remain in the spa when it’s not in use.