38
Press: Blower buon on main control to acvate system.
1) ON/OFF :
1
st
Press: The Blower starts at maximum Speed. LED: ON
2
nd
Press: The blower stops. LED: OFF
2) TO CONTROL SPEED:
Press and hold: Speed goes up or down, LED: ON when pressing.
Release pressure at the desired speed.
3) TO CONTROL PULSATION:
1
st
Press: Slow Pulsaon Cycle, LED: ON.
2
nd
Press: Quick Pulsaon Cycle, LED: Flashes.
3
rd
Press: Pulsaon Cycle OFF, LED: OFF.
1
2
3
TOPSIDE PANEL DISPLAY MESSAGES
Hr - An internal hardware error has been detected
Prr - The Prr error message indicates a problem with the regulaon probe. The system is constantly verifying if the
temperature probe reading is within its normal limits.
HL - The water temperature at the heater has reached 119
o
F (48
o
C). Do not enter spa water.
FLO - The system did not detect any water flow while the filtraon pump was running.
UPL - No low level configuraon soware has been downloaded into the system.
AOH - The temperature inside the spa skirt is too high, causing the internal temperature in the spa pack to increase above
the normal limits.
OH - The water temperature in the spa has reached 108
o
F (42
o
C). Do not enter spa water.