Duramax/Duramax Hyamp Robotic Torches Service Manual 807460 55
4 – Component Replacement
Disconnect the power, gas supply, and torch
1. Turn the plasma power supply switch to OFF (O).
2. Turn the line disconnect switch to OFF (O).
3. Disconnect the gas supply hose from the plasma power supply.
4. Disconnect the torch from the plasma power supply.
Figure 23