Bring the torch front and center so it can be removed and checked over
Note the yellow crosshairs on the monitor mark the torch location
To move the torch: Machine->Move To (OR press V)
Click the new location and the torch will move (Keep Clear)
A 7/16” open end wrench is needed
Loosen the nut closest to the inside of the carriage
Loosen the thumb bolt on the right
The torch should slip out easily
Remove the shield from the torch
Remove the retaining cap from the torch
Remove the nozzle from the torch
Remove the electrode from the torch
Remove the swirl ring from the torch
Check each for any damage per the specifications
Reinstall in the opposite manner
Ensure proper torque (no tools to tighten on the torch)
Ensure the torch is flush and plumb when remounted on the carriage