Powermax1000/1250/1650
PA IGBT Replacement
Remplacement du PA IGBT du
Powermax1000/1250/1650
Field Service Bulletin
Bulletin de service sur le terrain
806370 – Revision 0 – June, 2009
Révision 0 – Juin, 2009
Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 1650 and is the answer not in the manual?

Hypertherm Powermax 1650 Specifications

General IconGeneral
Gas SupplyAir or Nitrogen
Recommended Gas Flow Rate200-300 L/min
Air Pressure Requirement6-8 bar
Air Flow Requirement300 L/min
Dimensions800 x 600 x 1200 mm

Summary

Introduction to PA IGBT Replacement

Purpose of PA IGBT Replacement

Describes the necessary steps to replace the PA IGBT in the Powermax1000, 1250, and 1650 models.

Tools and Materials for IGBT Replacement

Required Tools

Lists the necessary tools, including a #2 Phillips screwdriver.

Kit Contents by Model

Details parts included in kits for Powermax1000, 1250, and 1650 models.

PA IGBT and Gate-Drive Wire Replacement Procedure

Safety Precautions

Warning about electric shock and the need to disconnect power before performing any maintenance.

Step-by-Step Replacement Guide

Detailed instructions for removing the old PA IGBT and installing the new one, including torque specifications.