Site Overview & Planning
Revision C Installation 1-1
,QVWDOODWLRQ
Chapter 1
6
,7(29(59,(:3/$11,1*
)LJXUH
SlideSmart DC 15 SlideSmart DC 10F
Duty cycle: continuous Duty cycle: continuous
Power, single phase: Switch selectable Power, single phase: Switch selectable
115 volts, 3 amps, 50/60 Hertz 115 volts, 3 amps, 50/60 Hertz
230 volts, 1.5 amps, 50/60 Hertz 230 volts, 1.5 amps, 50/60 Hertz
Motor:
½ hp Motor: ½ hp
Gate speed: 1ft/s Gate speed: 2ft/s
Gate weight: Maximum 1500lbs (675kg) Gate weight: Maximum 1000lbs (450kg)
Note:For SlideSmart DC Solar operators, refer to www.hysecurity.com
Pedestrian gate
2” x 2” screen (minimum height = 48”)
Maximum 3” (7.6cm) width
between vertical bars
Target magnet on chain
Photo eye (entrapment protection shown in four locations)
Physical stop - weld stops at both ends of V track
Earth ground
Edge sensor
Edge sensor on
V track
Photo eye
Physical
stop
Make sure a separate walk-
through entrance is avail-
able and its pedestrian
path is clearly
designated.
Attach WARNING Signs
Be sure to place the
WARNING signs on both
sides of the gate. For your records, take a
photograph of the completed installaon site.
WARNING