Questions and Answers:

HySecurity StrongArmPark DC 10 Specifications

General IconGeneral
Motor TypeDC
UL RatingUL 325
Max Gate Weight1, 000 lb (454 kg)
Max Gate Length20 ft (6.1 m)
Operating Temperature-13°F to 158°F (-25°C to 70°C)

Summary

Welcome to HySecurity

Contact Information

Provides contact details for HySecurity distributors and technical support.

Notices and Bulletins

Information for installers regarding product updates and support.

Supplemental Documents

Lists resources for planning, installation, operation, and maintenance.

Hazardous Materials and Proper Disposal

Guidelines for handling and disposing of hazardous materials in gate operators.

Important Safety Information

Safety - Additional Installer Responsibility

Details installer duties for safe gate operator installation and compliance.

Safety - Owner/User Responsibility

Outlines responsibilities for safe operation and maintenance for owners/users.

Identifying Gate Operator Category and Usage Class

Explains the four UL 325 vehicular usage classes for gate operators.

Choosing Secondary Entrapment Protection

Guides selection of secondary entrapment sensor devices based on UL 325 requirements.

Wind Load Factors & Site Prep

Discusses wind load considerations and site preparation for gate operators.

Manual Release

Instructions on how to manually operate the gate arm in case of power loss.

Breakaway Arm Feature

Describes the breakaway arm bracket that reduces damage from vehicle impacts.

Dynamic Reversing Sensor

Explains the sensor that stops and reverses the arm to prevent entrapment.

Safety Notices

Defines the four levels of safety notices used in the manual (Danger, Warning, Caution, Notice).

Common Industrial Symbols

Explains common international safety symbols used for hazard alerts.

Power

Installing the Earth Ground

Details how to install a proper earth ground for electrical safety and performance.

Wiring AC Power

Instructions on connecting the gate operator to AC power sources.

Wiring 115VAC Power

Specific steps for connecting the operator to a 115VAC power supply.

Wiring 208/230VAC Power

Steps for connecting the operator to 208/230VAC power supplies.

Connecting DC Power

Instructions for connecting the DC power supply to the operator.

Turning the Power Switch ON

Details the process and expected behavior when turning power on.

Display & Menu Options

Initial Setup

Guides for initial setup after installation, using software or keypad.

Understanding the Display and Keypad

Overview of the display interface and keypad functions for operator control.

Menu Mode

Explains the Menu Mode for configuration and data entry.

Menu Mode Navigation

How to navigate through the operator's menus using the keypad buttons.

Run Mode

Describes the operator's state when ready for commands or in motion.

Viewing Operator Status Displays

How to view status information like software version and gate handing.

User Menu

User Menu: Table 1

Details user menu items, settings, and their explanations with wire connections.

Installer Menu

Access

How to access the Installer Menu via the keypad and specific button combinations.

Installer Menu: Table 2

Lists installer menu items, setting options, tasks, and SDC wire connections.

Setting the Time and Date

Procedure for setting the operator's internal clock and date.

Resetting Open and Close Limits

Instructions for resetting the gate's open and close limits.

Learn Open Limits

Steps to manually teach the operator the full open position for the barrier arm.

Learn Close Limits

Steps to manually teach the operator the full close position for the barrier arm.

Test the Operator

How to test the gate operator's functionality after installation or adjustments.

Setting the Close Timer

Procedure to configure the automatic closing delay time for the barrier arm.

SDC Inputs & Wiring

Overview of the Smart DC Controller

Explains the Smart DC Controller's LEDs, inputs, and basic functionality.

Integrating with Security Systems

Details how to connect and integrate operators with central security systems via RS-485.

Smart DC Controller Inputs

Describes the inputs available on the Smart DC Controller and their functions.

SDC Terminal Inputs

Lists and describes the specific terminal inputs on the SDC board for various controls.

Connecting Accessory Devices

How to connect external devices like sensors and access controls to the SDC.

User Relays - Programming Procedure

Guide to programming the programmable output relays for various functions.

Revenue Control Parking Applications

Explains how to configure relays for parking lot revenue control applications.

Extended Relay Module Option

Information about the optional extended relay module for additional terminals.

Vehicle Detector Logic

How to configure vehicle detector functions for gate closing logic.

Vehicle Detector Logic Mode Selection

Setting anti-tailgate modes for vehicle detectors and their compatibility.

TailGate Alert

How to use User Relay 1 for tailgating vehicle notification.

Vehicle Detector Installation: HY-5A

Instructions for installing the HySecurity HY-5A vehicle detector module.

Connecting HY-5A Vehicle Detectors

Step-by-step guide for connecting the HY-5A vehicle detector modules.

Installing Standard 11-Pin Box Type Vehicle Detectors

Procedure for installing standard 11-pin box type vehicle detectors.

Photo Eyes (Non-Contact) Installation

Guidance on planning and installing photo eyes for safety and detection.

Compatibility

Requirements for photo eye sensor compatibility with UL 325 standards.

Installation

Steps for installing additional photo eyes according to site layout.

Configuration

How to configure photo eyes based on their operating mode and output type.

Photo Eye Connections

Connecting the wires from the photo eye receiver and emitter to the controller.

Photo Eye Alignment

Using the buzzer feature to align photo eyes for optimal performance.

Monitored Connection

Enabling monitored connection for photo eye fault detection.

Photo Eye Function

Explains the behavior of photo eyes during gate operation and fault conditions.

Troubleshooting

System Diagnostic Messages

How the controller reports malfunctions via codes, buzzers, and gate stops.

Troubleshooting Codes

Details common alerts, faults, and errors, their causes, and suggested corrective actions.

Adjusting the Dynamic Reversing Sensor

How to adjust the sensitivity of the dynamic reversing sensor for gate operation.

Conditions Affecting the Dynamic Reversing Sensor

Factors like wind and gate condition that can affect reversing sensor performance.

StrongArmPark DC Wiring Schematics

StrongArmPark DC Solar Wiring Schematics

Wiring diagrams specific to the solar-powered StrongArmPark DC models.

General Maintenance

Smart Touch Analyze and Retrieve Tool (S.T.A.R.T.)

Overview of the S.T.A.R.T. software for managing gate operator settings and diagnostics.

What You Need

Lists the requirements for using the S.T.A.R.T. software, like cables and RAM.

Installing S.T.A.R.T. Software

Step-by-step instructions for downloading and installing the S.T.A.R.T. software.

Software Maintenance

Importance of keeping SDC board software updated for new features.

Electrical Controls

Basic maintenance advice for electrical components and enclosure.

Clock Battery Replacement

Guidance on replacing the coin battery that maintains the clock.

Fuse Replacement

Information on locating and replacing the main fuse on the SDC board.

HyProtectTM Breakaway Arm Mount

Information on replacing breakaway arm fasteners based on arm length and wind conditions.

Mechanical Maintenance

Routine mechanical checks, including drive belt, rust, and battery replacement.

Drive Belt Tension and Alignment

Steps to check and adjust drive belt tension and alignment for optimal performance.

DC Battery Replacement

Details on identifying low battery indicators and the process of replacing batteries.

Reference

Handing Change

Step-by-step guide to changing the gate operator's handing configuration.

Spring & Physical Stop Lever Assembly

Instructions for adjusting spring tension and physical stop lever settings.

Set Handing

How to set the gate operator's handing (left/right) using the Smart DC Controller.

StrongArmPark DC Center Loop Layout

Diagram and dimensions for installing vehicle detector loops for traffic control.

StrongArmPark DC Center Loop Configuration

Explains connecting HY-5A or generic box vehicle detectors to the SDC controller.

StrongArmParkDC Loop Layout Sequenced Gates #1

Describes loop layout for sequencing two gate operators in the first configuration.

StrongArmParkDC Loop Layout Sequenced Gates #2

Describes loop layout for sequencing two gate operators in the second configuration.

Limited Warranty

Warranty

Details the terms and duration of the limited warranty for HySecurity products.

Exclusion of Other Warranties

Disclaims all warranties not expressly stated, including merchantability and fitness.

Buyer's Exclusive Remedies for Any Nonconformity

Outlines the buyer's remedies in case of product nonconformity, such as repair or refund.

Exclusion of Consequential and Incidental Damages

Limits HySecurity's liability for indirect, special, or consequential damages.

Severability

States that if any provision is invalid, the remainder of the warranty remains in effect.

Applicable Law

Specifies that Washington state law governs the warranty terms and conditions.