ibaBM-DDCS
36
Issue 1.11
Locked
True: No changes possible. Only authorized users can unlock modules.
False: Any user can make changes
Enabled
True: Data acquisition is enabled for this module
False: Data acquisition is not enabled for this module
Name
Name of the module
Module No.
Logical number of the module
Timebase
Acquisition timebase used for this module
Use name as prefix
If TRUE is selected, the module name is placed in front of the signal name as
prefix.
Advanced
Enable default values
True: In the event of a timeout, the last transmitted value will be
overwritten by the default value. The default value can be preset in the
Analog and Digital tabs.
False: In the event of a timeout, the last transmitted value will remain
Module Layout
No. analog signals:
Number of lines in the Analog tab
No. digital signals:
Number of lines in the Digital tab
Browse
In order to select the data set signals, click on Browsein the bottom field. The data set
browser will open and the nodes (drives) will be displayed. The symbols mean:
Red node: no response received from the node
Green node: response received from the node
In the tree structure, select the signal via the node number, the data set number and the
index. The signal is added to the signal grid by double clicking on the desired signal or
clicking on the <Add> button.