4-1
MAINTENANCE
DC SERIES BOILERS / WATER HEATERS DC 15-95, DC 15-96, DC 20-125, DC 33-160
MAINTENANCE4.0
BOILER / WATER HEATER
MAINTENANCE
4.1.1 General Care
Keep combustible materials and ammable liquids and vapours away from the boiler
/ water heater.
Keep vent terminals clear of obstructions (snow, dirt, etc.).
4.1.2 Inspection
Inspection of the boiler / water heater is to be performed annually by a
qualied service technician.
4.1.3 Venting
Check vent terminals for and remove any obstructions (e.g. leaves, dust, other
debris).
Check, and clean or replace intake air lters or screens as required.
Check for holes or leaks in venting. Replace venting as needed.
Examine for any signs of moisture caused by sweating intake air pipes;
insulate as required.
Ensure proper resealing or reinstallation of venting on each servicing.
4.1.4 Condensate Traps
Condensate trap must be examined every two months to see if cleaning is
necessary (refer to trap cleaning instructions, section 1.5.3 of this manual).
Ensure that trap has been re-lled completely before ring boiler / water
heater.
If condensate neutralization is used, check pH level of condensate discharge.
4.1.5 Burner
Annually, remove burner to inspect for extent of fouling (refer to burner
removal and reassembly instructions, section 3.5.1 of this manual). Blow clear
using compressed air. Ensure ame is stable and without excessive uttering.
Normal ame pattern is evenly distributed over the burner surface.
If burner is operating improperly, remove and clean or replace. Use a CO
2
analyzer to determine proper combustion. See Table 11, page 3-3 for correct
values.
4.1
CAUTION
Label all wires prior to
disconnection when servicing
controls. Wiring errors
can cause improper and
dangerous operation.
CAUTION
The owner is responsible
for general care of the boiler
/ water heater. Improper
maintenance of the boiler /
water heater may result in a
hazardous condition.
WARNING
Whenever the burner is
removed for inspection or
boiler / water heater servicing,
the sealing gaskets must be
examined and replaced if
damaged.Upon re-assembly,
an approved leak test solution
must be applied around the
burner ange sealing area to
ensure there is no leakage of
combustible gas/air premix.
WARNING
Fill trap with water before
boiler / water heater is rst
red to prevent exhaust
fumes from entering room.
Never operate the boiler /
water heater unless the trap
is lled with water.
Failure to
comply will result in severe
personal injury or death.
Figure 38: Ignitor Gap - 3/16” / 4.5mm
CAUTION
Periodic inspection of
Low Water Cut-Off Device
including ushing of oat
types is required, if installed
as an accessory to the boiler /
water heater.

Table of Contents

Other manuals for IBC DC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBC DC Series and is the answer not in the manual?

IBC DC Series Specifications

General IconGeneral
BrandIBC
ModelDC Series
CategoryBoiler
LanguageEnglish

Related product manuals