IBERITAL DE RECAMBIOS, S.A.
• Failure in the volumetric counter (5 seconds)
The LED of the erogation being used (1 short coffee, 2 long coffee ...) is winking due to some failure
in the volumetric counter. At the same time, this erogation does not stop.
• Failure in the volumetric counter (erogation)
This alarm appears when the erogation time is too long. At the same time, this problem
appears when the coffee is ground too fine or too many grams.
1.4.- HOT WATER OUTPUT
Place a cup or other receptacle under the hot water jet (8). Push the button (19) to start the hot water
feed, release this button to stop it.
1.5.- STEAM OUTPUT
Point the steam jet (9) towards the drip tray (16).
Turn the control (7), to discharge the condensation, until steam escapes from the opening.
Place the steam jet (9) into the recipient containing the liquid which is to be heated. Turn the control
(7) to release the steam. To obtain a frothy cappuccino keep the jet level with the top of the cold milk,
this will create froth.
When the liquid has reached the desired temperature, stop the steam feed by turning off the control (7)
on the contrary.
Slide the recipient out from under the steam jet (7). Point the stream jet (7) towards the drip tray (16).
Briefly turn the control (7) on, to discharge any residue which has remained in the steam jet (9). Clean
the outside of the steam jet (9) with a damp clothe or sponge.
MANUAL NEW IBERITAL INGLES Página 10 de 30
11/05/2007