To install the transport handle and plug: introduce the handle [K] into the safety ring [L] provided on
the plug chain and in the special nuts [M]. Introduce the handle into the two holes in the top part of
the machine and lock it with the special nuts [N]. Use a suitably sized hex nut wrench to tighten.
5.3 WARNINGS AND RECOMMENDATIONS BEFORE STARTING UP
Before controlling compressed air supply, make sure that the air hose connection is compatible with
the coupling on the anti-condensate filter.
To check that your IBIX is operating correctly, start it up for the first time with an empty tank.
To operate the machine, make sure that the safety spring is inserted in its special housing below the
starter trigger.
On starting up the machine, the abrasive material adjustment screw control should be kept turned off
and then gradually turned on until the required abrasive delivery flow rate is obtained.
After work, it is always advisable to empty the machine tank (for more information check chapter 7 -
Maintenance).