Large-cluster models
11
L,
11
R,
12R, and 13R have 2MB base storage in one card
slot.
Two
other slots can hold storage expansion cards that can
provide
a possible
total of 6MB. However, if these
controller
models run under Configuration
Support-A
or
-S
Release 5.0, 4MB of that possible total is supported. If the
controller
models
are
supported by Configuration Support-B, 6MB of storage is
supported.
Large-cluster models 1
L,
1
R,
2R, and
3R
have 1 MB base storage in one card slot.
Two
other
slots can hold storage expansion cards that provide a possible total of
6MB (if a 2MB card replaces the 1 MB card in the
first
slot). However, if these
controller
models run under Configuration Support-A
or
-S Release 5.0, 4MB of that
possible total is supported.
If the
controller
models
are
supported by Configuration
Support-B, 6MB of storage is supported.
Medium-cluster
models
51
Rand
53R have 1 MB of base storage. As much as 2MB
of storage can be added to
this
base amount (using the one card slot)
for
a
possible total of 3MB. The Model 52R has 512KB of base storage. Storage can be
expanded on this model to a
maximum
of 1.5MB.
Medium-cluster
models
61
R,
62R, and 63R have 2MB of storage and can be
expanded to as much as 4MB (using the one module slot).
Storage expansion
is
not supported in the
small-cluster
models of
the
controller.
Models
81
Rand
82R
have 1 MB of base storage, and models
91
Rand
92R have
2MB of base storage.
Encrypt/Decrypt Adapter
The Encrypt/Decrypt
Adapter
feature
is
supported in the following:
Configuration Support-A (Release 3 and higher)
Configuration Support-S (Release 4 and higher).
It is supported on models 1
R,
2R,
and
3R.
Concurrent Communication Adapter (CCA)
The Concurrent Communication Adapter (CCA) enables
large-
and
medium-cluster
controllers
to communicate
simultaneously
with additional host processors. Each
processor card provides one additional communications link. When the Concurrent
Communication Adapter is installed in a controller, the
terminals
attached to the
controller
can communicate
with
each host to which the
controller
is
attached, with
the exception of
ASCII
terminals.
An optional feature, the Concurrent Communication Adapter does not affect
compatibility
with existing host interfaces, host software
or
protocols,
or
3174
features and functions.
Small-cluster
controllers
do
not support
this
adapter, and
medium-cluster
models
52R and 53R do not support it. It
is
optional on all
other
models. For
more
information about the Concurrent Communication Adapter, see
your
IBM marketing representative.
Chapter
2.
Features and Functions of the 3174
Controller
2-11

Table of Contents

Other manuals for IBM 3174

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 3174 and is the answer not in the manual?

IBM 3174 Specifications

General IconGeneral
BrandIBM
Model3174
CategoryController
LanguageEnglish

Related product manuals