EasyManua.ls Logo

IBM 3270 - Signal Cabl~ Considerations; Cable R:foq · Ments

IBM 3270
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signal Cable Considerations
When the IBM 3270 Connection adapter is attached
to
a host
system, consider the following:
e Installation
Cable runs (indoor
and
outdoor)
Types
of
signal cables
and
specifications (coaxial
and
twisted-pair)
Signal cable
and
power line separation
Cable labeling
and
testing.
Cable accessories.
Outdoor
runs require additional installation guidelines, including
lightning protection.
For
more information, refer
to
the list
of
IBM
signal cable publications
on
page
6.
Cable Requirements
Table 1 shows the adapter requirements for various signal cable
types
and
IBM products.
Table
1.
Cable Requirements
Telephone
IBM
Coaxial
IBM
Cabling
IBM
Cabling
Twisted-Pair
Model
RG62A/U
System
Type
1
System
Type
9 Type3
IBM
3270
BNC
Yesl
Yesl Yes2
Con-
nection
Adapter
IBM
3299
BNC
Yes3
Yes3
Yes2
Model
1
or
3274
IBM
3299
BNC
Yesl
Yesl Yes2
Model
2
or
3174
IBM
3299
NA NA
NA
Yes4
Model 3
NA
=
Not
applicable
1 Dual purpose connector (D PC)
2 IBM/ROLM Coax-to-Twisted-Pair Adapter (CTPA)
3 IBM Cabling System balun
4 Modular jack connector