11
You have stations
that
are not indicated
on
any
status screen,
or
a Cluster Access Error.
1.
Run
the system diagnostic tests on a station
that
is
not indicated
on
any status screen,
or
that
has a Cluster Access Error.
r"\
2.
If
the diagnostic test fails, have the unit that
contains the
adapter
serviced.
3.
If
the diagnostic test passes, continue doing
the diagnostic tests until all
of
the stations
that
did
not
appear
on
any status screen
presentation
or
had a Cluster Access Error
are tested.
4.
If
the Cluster Adapters check good and the
stations did not appear
on
the Cluster status
screen presentations, contact your
Installation Manager as the coaxial cable
or
a
terminating plug
is
suspect.
".-.....,
Note:
If
you have more
than
one
Cluster
Adapter
installed in your system go back to
2200-1, and continue until all
of
the Cluster
Adapters are tested.
2200-12