Figure 122. Removing the service access cover
Removing the drive backplane power cable from the 9009-41A, 9009-41G, 9009-42A,
9009-42G, or 9223-42H system
To remove the drive backplane power cable from the system, complete the steps in this procedure.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. For a rack-mounted system, lift the air baffle (A) straight up as shown in Figure 123 on page 138
.
For a stand-alone system, remove the air baffle (A) straight out as shown in Figure 124 on page 139.
Place the air baffle upside down on a clean area.
Drive backplane cables in the 9009-41A, 9009-41G, 9009-42A, 9009-42G, or 9223-42H
137