Table 7. Server events (continued)
Event Event Type Severi
ty
Message Description Cause User Action
pci_riser_temp_failed STATE_CHANGE ERRO
R
The
temperature of
PCI Riser {0} is
too high. ({1})
The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
server_fan_ok STATE_CHANGE INFO Fan {0} is ok.
({1})
The GUI
checks the
hardware
state using
xCAT.
The hardware
part is ok.
None.
server_fan_failed STATE_CHANGE ERRO
R
Fan {0} failed.
({1})
The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
dimm_ok STATE_CHANGE INFO DIMM {0} is ok. The GUI
checks the
hardware
state using
xCAT.
The hardware
part is ok.
None.
dimm_failed STATE_CHANGE ERRO
R
DIMM {0} failed. The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
pci_ok STATE_CHANGE INFO PCI {0} is ok. The GUI
checks the
hardware
state using
xCAT.
The hardware
part is ok.
None.
pci_failed STATE_CHANGE ERRO
R
PCI {0} failed. The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
fan_zone_ok STATE_CHANGE INFO Fan Zone {0} is
ok.
The GUI
checks the
hardware
state using
xCAT.
The hardware
part is ok.
None.
fan_zone_failed STATE_CHANGE ERRO
R
Fan Zone {0}
failed.
The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
drive_ok STATE_CHANGE INFO Drive {0} is ok. The GUI
checks the
hardware
state using
xCAT.
The hardware
part is ok.
None.
drive_failed STATE_CHANGE ERRO
R
Drive {0} failed. The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
dasd_backplane_ok STATE_CHANGE INFO DASD
Backplane {0} is
ok.
The GUI
checks the
hardware
state using
xCAT.
The hardware
part is ok.
None.
dasd_backplane_failed STATE_CHANGE ERRO
R
DASD
Backplane {0}
failed.
The GUI
checks the
hardware
state using
xCAT.
The hardware
part failed.
None.
14 IBM Elastic Storage System 3000: Service Guide

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Elastic Storage System 3000 and is the answer not in the manual?

IBM Elastic Storage System 3000 Specifications

General IconGeneral
BrandIBM
ModelElastic Storage System 3000
CategoryStorage
LanguageEnglish

Related product manuals