IBM 15 Service Manual
41
10.2. D-SUB Connector (Digital)
x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
00 00 FF FF FF FF FF FF 00 24 4D 51 A1 01 01 01 01
16: 10 0D 01 03 80 1E 17 78 EA 71 F5 9F 55 4B 99 24
32: 1C 4F 54 AF EE 00 31 40 45 40 61 40 01 01 01 01
48: 01 01 01 01 01 01 64 19 00 40 41 00 26 30 18 88
64: 36 00 30 E4 10 00 00 18 00 00 00 FD 00 37 4B 1E
80: 3F 08 00 0A 20 20 20 20 20 20 00 00 00 FF 00 33
96: 31 36 30 30 30 31 0A 20 20 20 20 20 00 00 00 FC
112 00 49 42 4D 4C 31 35 30 2F 4C 31 35 30 70 00 B9
Note: Byte 0C, 0D, 0E, 0F means Serial No. Byte 10, 11 means Manufacture Time. Byte
7F means checksum