Table 28. Error event IDs and error codes (continued)
Event
ID
Notification
type Condition
Error
code
010030 E A managed disk error recovery procedure (ERP) has
occurred. The node or controller reported the following:
v Sense
v Key
v Code
v Qualifier
1370
010031 E One or more MDisks on a controller are degraded. 1623
010032 W The controller configuration limits failover. 1625
010033 E The controller configuration uses the RDAC mode; this is
not supported.
1624
010034 E Persistent unsupported controller configuration. 1695
010040 E The controller system device is only connected to the
node through a single initiator port.
1627
010041 E The controller system device is only connected to the
node through a single target port.
1627
010042 E The controller system device is only connected to the
clustered system nodes through a single target port.
1627
010043 E The controller system device is only connected to the
clustered system nodes through half of the expected
target ports.
1627
010044 E The controller system device has disconnected all target
ports to the clustered system nodes.
1627
010050 W A solid-state drive (SSD) failed. A rebuild is required. 1201
010052 E A solid-state drive (SSD) is offline as a result of a drive
hardware error.
1205
010053 E A solid-state drive (SSD) is reporting a predictive failure
analysis (PFA).
1215
010054 E A solid-state drive (SSD) is reporting too many errors. 1215
010055 W An unrecognized SAS device. 1665
010056 E SAS error counts exceeded the warning thresholds. 1216
010057 E SAS errors exceeded critical thresholds. 1216
010058 E The drive initialization failed because of an unknown
block size or a block size that is not valid; an unknown
capacity or a capacity that is not valid; or was not able to
set the required mode pages.
1661
010059 E A solid-state drive (SSD) is offline due to excessive
errors.
1311
010060 E A solid-state drive (SSD) exceeded the warning
temperature threshold.
1217
010061 E A solid-state drive (SSD) exceeded the offline
temperature threshold.
1218
010062 E A drive exceeded the warning temperature threshold. 1217
010063 W Drive medium error. 1321
010066 W Controller indicates that it does not support descriptor
sense for LUNs that are greater than 2 TBs.
1625
Chapter 9. Event reporting 131