1189 The node is held in the service state.
Explanation: The cluster is reporting that a node is
not operational because of critical node error 690. See
the details of node error 690 for more information.
User response: See node error 690.
1202 A solid-state drive is missing from the
configuration.
Explanation: The offline solid-state drive (SSD)
identified by this error must be repaired.
User response: In the management GUI, click
Troubleshooting > Recommended Actions to run the
recommended action for this error. Otherwise, use MAP
6000 to replace the drive.
1691 A background scrub process has found
an inconsistency between data and
parity on the array.
Explanation: The array has at least one stride where
the data and parity do not match. RAID has found an
inconsistency between the data stored on the drives
and the parity information. This could either mean that
the data has been corrupted, or that the parity
information has been corrupted.
User response: Follow the directed maintenance
procedure for inconsistent arrays.
1189 1691
Chapter 9. Event reporting 157

Table of Contents

Other manuals for IBM Storwize V7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 and is the answer not in the manual?

IBM Storwize V7000 Specifications

General IconGeneral
ModelStorwize V7000
Storage TypeHybrid Flash Array
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive TypesSSD, SAS
Host Interface8 Gbps Fibre Channel, 16 Gbps Fibre Channel, 1 Gbps iSCSI, 10 Gbps iSCSI, 12 Gbps SAS
Maximum Cache32GB
Operating System SupportIBM AIX, Linux, Windows, VMware
Data Reduction FeaturesReal-time Compression
Management SoftwareIBM Spectrum Virtualize

Related product manuals