Table 7. DSA Preboot messages
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number Component Test State Description Action
089-801-xxx CPU CPU Stress Test Aborted Internal program
error.
1. Turn off and restart the system.
2. Make sure that the DSA code is at
the latest level. For more information
and to download the utilities, go to
http://www.ibm.com/systems/support/
supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-DSA.
3. Run the test again.
4. Make sure that the system firmware is
at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD
section for this component. For more
information, see “Updating the
firmware” on page 267.
5. Run the test again.
6. Turn off and restart the system if
necessary to recover from a hung
state.
7. Run the test again.
8. Replace the following components
one at a time, in the order shown,
and run this test again to determine
whether the problem has been
solved:
a. (Trained service technician only)
Microprocessor board
b. (Trained service technician only)
Microprocessor
9. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
96 IBM System x3100 M4 Type 2582: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3100 M4 Type 2582

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 Type 2582 and is the answer not in the manual?

IBM System x3100 M4 Type 2582 Specifications

General IconGeneral
BrandIBM
ModelSystem x3100 M4 Type 2582
CategoryServer
LanguageEnglish

Related product manuals