10. If you are instructed to return the power supply, follow all packaging
instructions, and use any packaging materials for shipping that are supplied to
you.
Installing the non-hot-swap power supply
This procedure applies only to 4U server models with non-hot-swap power supplies.
Statement 8:
CAUTION:
Never Remove the server top cover on a power supply or any part that has
the following label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
To install a non-hot-swap power supply on 4U server models with non-hot-swap
power supplies, complete the following steps.
1. Remove the air duct.
2. Remove the heat sink (see “Removing the microprocessor and heat sink” on
page 250).
3. Position the power supply in the chassis so that the screw holes in the power
supply are aligned with the corresponding holes in the rear of the chassis.
242 IBM System x3100 M4 Type 2582: Problem Determination and Service Guide