v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code Description Action
0058008 DIMM failed memory test. Note: Each time you install or remove a DIMM, you
must disconnect the server from the power source;
then, wait 10 seconds before restarting the server.
1. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
2. Swap the affected DIMMs (as indicated by the
error LEDs on the system board or the event logs)
to a different memory channel or microprocessor
(see “Installing a memory module” on page 203).
3. If the problem is related to a DIMM, replace the
failing DIMM (see“Removing a memory module”
on page 200 and “Installing a memory module” on
page 203).
4. (Trained service technician only) If the problem
occurs on the same DIMM connector, check the
DIMM connector. If the connector contains any
foreign material or is damaged, replace the
system board (see “Removing the system board”
on page 258 and “Installing the system board” on
page 261).
5. (Trained service technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged pins.
If a damage is found, replace the system board
(see “Removing the system board” on page 258
and “Installing the system board” on page 261).
6. (Trained service technician only) If the problem is
related to microprocessor socket pins, replace the
system board (see “Removing the system board”
on page 258 and “Installing the system board” on
page 261).
7. (Trained Service technician only) Replace the
affected microprocessor (see“Removing the
microprocessor and heat sink” on page 250 and
“Installing a microprocessor and heat sink” on
page 254).
00580A1 Invalid DIMM population for mirroring mode
1. If a fault LED is lit, resolve the failure.
2. Install the DIMMs in the correct sequence (see
“Installing a memory module” on page 203).
00580A4 Memory population changed. Information only. Memory has been added, moved, or
changed.
00580A6 Spare failover detected. Information only. Memory redundancy or spare rank
has been lost. Check the event log for uncorrected
DIMM failure events (see “Event logs” on page 24).
34 IBM System x3100 M4 Type 2582: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3100 M4 Type 2582

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 Type 2582 and is the answer not in the manual?

IBM System x3100 M4 Type 2582 Specifications

General IconGeneral
Form FactorTower
ChipsetIntel C202
Memory Slots4 DIMM slots
ProcessorIntel Pentium
MemoryUp to 32GB DDR3
StorageUp to 4 x 3.5"
Power Supply350W
Network InterfaceIntegrated Gigabit Ethernet
RAID SupportRAID 0, 1
Expansion Slots1 PCI
USB Ports6 x USB 2.0 (2 front, 4 rear)
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server

Related product manuals