Table 7. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints, tips, and
new device drivers or to submit a request for information.
Message
number Component Test State Description Action
202-901-xxx Memory Memory Stress
Test
Failed Test failure.
1. Run the standard memory test to
validate all memory.
2. Make sure that the DSA code is at
the latest level. For more information
and to download the utilities, go to
http://www.ibm.com/systems/support/
supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-DSA.
3. Turn off the system and disconnect it
from power.
4. Reseat the DIMMs.
5. Reconnect the system to power and
turn on the system.
6. Run the test again.
7. If the failure remains, go to the IBM
website for more troubleshooting
information at http://www.ibm.com/
systems/support/supportsite.wss/
docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Chapter 3. Diagnostics
133