Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by ā€œ(Trained technician only),ā€ that step must be performed only by a trained
technician.
806f000d-0400xxxx
806f000d-0401xxxx
806f000d-0402xxxx
806f000d-0403xxxx
806f000d-0404xxxx
806f000d-0405xxxx
806f000d-0406xxxx
806f000d-0407xxxx
Drive n has been
added. (n = hard disk
drive number)
Info A drive has been
added.
No action; information only.
816f000d-0400xxxx
816f000d-0401xxxx
816f000d-0402xxxx
816f000d-0403xxxx
816f000d-0404xxxx
816f000d-0405xxxx
816f000d-0406xxxx
816f000d-0407xxxx
The Drive n Status has
been removed from
unit. (n = hard disk
drive number)
Error A drive has been
removed.
1. Reseat hard disk drive n.(n = hard
disk drive number). Wait 1 minute
or more before reinstalling the
drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware
and RAID controller firmware is at
the latest level.
4. Check the SAS cable.
806f010d-0400xxxx
806f010d-0401xxxx
806f010d-0402xxxx
806f010d-0403xxxx
806f010d-0404xxxx
806f010d-0405xxxx
806f010d-0406xxxx
806f010d-0407xxxx
The Drive n Status has
been disabled due to a
detected fault. (n = hard
disk drive number)
Error A drive has been
disabled because
of a fault.
1. Run the hard disk drive diagnostic
test on drive n.
2. Reseat the following components:
a. Hard disk drive (wait 1 minute
or more before reinstalling the
drive).
b. Cable from the system board
to the backplane.
3. Replace the following components
one at a time, in the order shown,
restarting the server each time:
a. Hard disk drive
b. Cable from the system board
to the backplane
c. Hard disk drive backplane
(n = hard disk drive number)
806f020d-0400xxxx
806f020d-0401xxxx
806f020d-0402xxxx
806f020d-0403xxxx
806f020d-0404xxxx
806f020d-0405xxxx
806f020d-0406xxxx
806f020d-0407xxxx
The Drive n Status has
a predictive failure. (n =
hard disk drive number)
Error A predictive failure
has been detected
for drive n.(n =
hard disk drive
number)
1. Replace the hard drive n.
(n = hard disk drive number)
54 IBM System x3100 M4 Type 2582: Problem Determination and Service Guide