v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 7978 and 1913 server,” on page 89 to determine which components are
CRUs and which components are FRUs.
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Beep code Description Action
3-2-4 Failed comparing CMOS memory size
against actual.
1. Reseat the following components:
a. DIMMs
b. System-board battery
2.
Replace the following components, one at
a time, in the order shown, restarting the
server each time:
a. DIMMs
b. System-board battery
c. (Trained service technician only)
System board
3-3-1 Memory size mismatch occurred.
1. Reseat the following components:
a. DIMMs
b. System-board battery
2.
Replace the following components, one at
a time, in the order shown, restarting the
server each time:
a. DIMMs
b. System-board battery
c. (Trained service technician only)
System board