Starting the Human Interface Infrastructure (HII) Configuration
Application
Use these instructions to start the Human Interface Infrastructure (HII) configuration
utility program.
To start the Human Interface Infrastructure (HII) configuration utility program,
complete the following steps:
1. Turn on the server.
Note: Approximately 1 to 3 minutes after the server is connected to ac power,
the power-control button becomes active after the power-on LED flashes slowly.
2. When prompted, <F1 Setup> is displayed, press F1. If you have set an
administrator password, you are prompted to type the password.
3. Under System Settings, select Storage.
When you have finished changing the settings, press Esc to exit from the program;
select Save to save the settings you have changed.
Creating RAID of hard disk drives (C105 only)
Notes:
1. If a ServeRAID adapter is installed in the server, ServeRAID C105 will not work.
2. ServeRAID C105 uses HII only for configuration and there is no legacy
configuration utility.
To create RAID of hard disk drives (C105 only), complete the following steps:
1. Turn on the server.
Note: Approximately 1 to 3 minutes after the server is connected to ac power,
the power-control button becomes active after the power-on LED flashes
slowly.
2. When prompted, <F1 Setup> is displayed, press F1. If you have set an
administrator password, you are prompted to type the password.
3. Under System Settings, select Storage.
4. Under Storage, select ServeRAID C105.
5. Under Configuration Options, select Virtual Drive Management Create
Configuration.
6. Select the type of array that you want to create.
7. Select Select Drives and use space key to select all the drives for your array.
8. Select Apply Change to create the array.
9. When the prompt Success is displayed, select OK to continue.
10. After the system auto skips to the next screen, select Save Configuration.
11. When the prompt Creating Virtual Drives will cause the data lost on the
associated Drives to be permanently deleted is displayed, use space key to
select Yes to continue.
12. Select OK to continue.
13. To initialize virtual disk, select ServeRAID C105 Virtual Drive Management
Select Virtual Drive Operation.
14. Select Start Operation.
15. Select Yes to confirm.
112 System x3630 M4 Type 7158: Installation and User’s Guide